SPECIFICATIONS:

  • 3000W max continuous power Modified Sine Wave Inverter
  • Automatic transfer switch 15 amp smart battery charger
  • Green LED indicates ac input power is functional and battery is charging
  • Transfer switch automatically switches when city power is lost
  • Red LED indicates ac input power is not functional and battery is being used
  • Dual ac receptacles
  • Over Temperature protection
  • Over Load protection
  • Single cooling fan operation
  • Internally fuse protected
  • ac output short circuit protection
  • Aluminum case for optimal cooling
  • Free 1 year tech support
  • 1 Year Warranty Parts and Labor
  • Surge power capability (peak power): 6000 Watts
  • dc input / operating voltage: 35 to 20 Volts
  • Output voltage: 120 Volts ac
  • Output frequency: 60 Hz +/1 .5 Hz
  • Battery low voltage alarm: 20.5 +/- 0.5 Volts
  • Battery low voltage shutdown: 20.0 +/- 0.5 V
  • No load minimum operating temperature: 25 degrees F
  • Full load maximum operating temperature: 140 degrees F (automatic shutdown)
  • Efficiency: 85-90%
  • No load draw @ 24V: 0.6 amps
  • AC amps: 25
  • DC amps: 125
  • High input voltage protection: 35V
  • Low input voltage shutdown: 20V
  • Internal fuse protection
  • <3 sec transfer time between loosing ac input power and switching to providing ac output power
  • Charger specs: 15 amp smart charger

PURE SINE WAVE INVERTER

  • Continuous output power: 300 Watts
  • Surge power capability (peak power): 600 Watts
  • dc input / operating voltage: 20.4 to 31 Volts
  • Output voltage: 120 Volts ac
  • Output voltage regulation: +/- 3%
  • Output wave form: pure sine wave
  • Output frequency: 60 Hz +/- 2hz
  • DC amps: 12.5
  • AC amps: 2.5
  • Battery low voltage alarm: 20.4-21.6 +/- 0.5 Volts
  • Battery low voltage shutdown: 18.4-19.6 +/- 0.5 Volts
  • No load power consumption: < 0.7 dc amps
  • Full load efficiency: 90%
  • 1/3 load efficiency: 95%
  • No load minimum operating temperature: -15 degrees Celsius
  • Full load maximum operating temperature: 55 degrees Celsius (automatic shutdown)
  • AC Output Socket Type: dual Type 2 -3 prong
  • High input voltage protection: 31V
  • Low input voltage shutdown: 20.4V
  • External blade fuse protection

24 Volt Solar Charge Controller

  • Input voltage: 33V-40V
  • Max input voltage: 45V
  • Max charging current: 30A
  • Constant voltage for battery: about 29.2V
  • Float voltage: 27V
  • LCD displays volts and current
  • Solar panel array: 6 AWG cable or larger
  • Battery: 6 AWG cable or larger
  • Selectable for both 12 volts and 24 volts
  • 2 State Charging
  • LCD Display - Voltage and current
  • LED Display - Power, Charging, Float, Reverse polarity, protection
  • Input protection
  • Reverse polarity protection
  • Gel or lead acid batteries
  • Battery check button
  • Short circuit protection
  • Solar over current protection
  • High Temperature protection

Batteries (system includes jTwo 12V, 100 AH special batteries)

  • Lead alloy with low calcium extends life of battery grid.
  • Through unique active material recipes, plates after undergoing curing and tank formation provide outstanding energy density and ensure the quality of the battery.
  • Using brass coated lead alloy battery terminals minimizes impedance of connecting cells inside.
  • Case made of ABS resin and cells kept under internal pressure protects from outer shock or impact.
  • Micro-porous AGM separator completely absorbs and retains electrolyte under the pressured cell design.
  • Electrolyte sufficiently serves for electrochemical reactions in battery but never spills.
  • Battery cases are sealed in epoxy and cells are covered with vents to avoid cell contamination with the atmosphere and serve for internal oxygen reaction.
  • With very little gas evolution, the water loss is minimized and service life is extended. Excess pressure and gas will be released which ensures safety.
  • Vent design is certificated by UL.

DISCHARGE RATES FOR COMBINED SYSTEM:

20hour rate (5.35A) 210.0Ah

10hour rate (10.0A) 200.0Ah

5hour rate (17.4A) 170.0Ah

3hour rate (26.0A) 150.0Ah

1hour rate (62.0A) 120.0Ah